The difference between Single
or Double Pole Thermostat is; the Single Pole Thermostat has no positive off,
while the Double Pole Thermostat has a positive off.
Single Pole Thermostat 24 volt for 120v, 208v, 240v & 277v models.
Double Pole Thermostat range 50° - 90° F temperature.
FEATURES:
Cabinet - 11 ga.
perforated steel housing powder coated with textured ivory finish. Heavy duty
end caps welded to the enclosure. Control compartment for housing thermostat
and disconnect switch is accessible by use of security type fastener.
Tamper proof left side
control panel houses built-in single pole thermostat - range 50° - 90°F
and disconnect switch.
Low operating temperatures
with tamper proof construction.
Limit Controls
- Linear limit type thermal overload with automatic reset covers full length
of heating element and shuts down heater when safe operating temperatures
are exceeded.
Controls - Temper
proof fasteners restrict access to controls. Built in thermostat and disconnect
switch with manual adjustment are located in control enclosure.
Element - All
steel high mass element construction with nickel-chromium resistance wire
embedded in
compacted efficient dialectric to ensure proper heat transfer. Aluminum fins
mechanically bonded
to steel tube allows for increased surface area and even heat transfer.
Brand Names
- Markel and Raywall
120
VOLT
TYPE
=
Institutional Wall
VOLT
= 120
WATT
= 1,000
BTU'S
= 3,413
AMPS
= 8.3
WEIGHT
(lbs) =
45
PHASE
= Single
LENGTH
= 36"
WARRANTY
= 1 Year
DIMENSIONS:
A = 36"
B = 18"
C (depth) = 5"
Minimum
Clearances:
4" to floor
12" to left side
Industrial Fans
Direct
6320 Evergreen Way, Ste 101
Everett, WA 98203 Sales: 866-727-1060 Support: 425-438-0990 Fax: 425-353-9058