CONSTRUCTION:
18 ga. steel cabinet with
powder coated finish and control compartment housing a master terminal board
with a hinged and latched access door, simplifying wiring, installation &
maintenance. Product Companies -
Markel and Raywall
HEATING ELEMENT:
Spiral fin steel element
with continuously brazed steel fins formed to allow side draw through air flow.
OVERHEAT PROTECTION:
All units come equipped
with automatic reset type limit to de-energize the heater should an over-temperature
situation occur.
FAN and MOTOR:
Totally enclosed,
1-speed 1-phase, permanently lubricated, thermally protected motors with unit
bearings on 3 KW - 20 KW models.
Totally enclosed, 2-speed, 1-phase, permanently lubricated, thermally
protected motors with sleeve bearings on 25 KW - 50 KW models.
Fan over-ride purges unit of residual heat at shutdown
LOUVER ASSEMBLY:
Louvers are individually
adjustable for directional control of air flow up to 15° from straight horizontal
Optional difusers available for down flow (vertical discharge) applications
TEMPERATURE CONTROLS:
Units with model
numbers ending in CA1 are factory wired for low voltage controls
25 KW through 50 KW units are designed for two stage heating operation
INTSTALLATION:
Unit Heaters can
be mounted for horizontal or vertical discharge
5100 Series suggested for applications up to 6,000 feet.
10' Horiz.; 14' Vert = RECOMMENDED MOUNTING HEIGHT
Control Votlage - 24
|
208
VOLT
|
| TYPE
=
Wall / Ceiling |
VOLT
=
208 |
TEMP.
RISE = 45°F |
| AIR
THROW = 22'
|
CFM
= 700 |
BTU'S
= 33,788 |
| PHASE
= 1
or 3 |
AMPS
= 47.8 / 27.4 |
WEIGHT
(lbs) =
55 |
| MOTOR
ENCLOSURE
= TE |
KW
= 9.9 |
WARRANTY
= 1 yr. limited |
DIMENSIONS:
- A = 24 5/16"
- B = 21 1/2"
- C = 6 1/2"