King W Wall Heater 120V 1000-500W Bright White - W1210-BW
King W Wall Heater 120V 1500-750W Bright White - W1215-BW
King W Wall Heater 240V 1000-500W Bright White - W2410-BW
King W Wall Heater 240V 1500-750W Bright White - W2415-BW
King W Wall Heater with Single Pole Thermostat Kit 120V 1500-750W Bright White - W1215-T-BW
King WHF Wall Heater 120V 1500-750W Bright White - WHF1215-BW
King WHF Wall Heater 240V 1000-500W Bright White - WHF2410-BW
King WHF Wall Heater 240V 1500-750W Bright White - WHF2415-BW
King WHF Wall Heater 240V 2000-1000W Bright White - WHF2420-BW
King PAW Wall Heater 120V 1500W Bright White - PAW1215-BW
King PAW Wall Heater 240V 2250W Bright White - PAW2422-BW
QMark CWH Commercial Fan-Forced Wall Heater 2560-5120 BTU 0.75/1.5 kW 120V 1 Phase CWH1151DSF
QMark CWH Commercial Fan-Forced Wall Heater 2560-6826 BTU 0.75-2.0 kW 208/240V 1 Phase CWH1202DSF
QMark CWH Commercial Fan-Forced Wall Heater 2560-6826 BTU 0.75-2.0 kW 240/277V 1 Phase CWH1207DSF
QMark CWH Commercial Fan-Forced Wall Heater 3413-6826 BTU 1.0/2.0 kW 208V 1 Phase CWH1208DSF
QMark SED Fan-Forced Wall Heater 5115 BTU 120 Volt 1500 Watts SED1512
QMark SED Fan-Forced Wall Heater 6826 BTU 240 Volt 2000 Watts SED2024
QMark QCH Ceiling Mounted Fan-Forced Heater 2560-6826 BTU 0.75-2.0 kW 240/277V 1 Phase QCH1207F
QMark QCH Ceiling Mounted Fan-Forced Heater 2560-6826 BTU 0.75-2.0 kW 208/240V 1 Phase QCH1202F
King KT Multi-Watt Kick Space Heater 120V 1500W Bright White - KT1215-MW-BW
King KT Multi-Watt Kick Space Heater 240/208V 1500W/1125W Bright White - KT2415-MW-BW
King KT Multi-Watt Kick Space Heater 120V 1500W Satin Black - KT1215-MW-SB
King KT Multi-Watt Kick Space Heater 240/208V 1500W/1125W Satin Black - KT2415-MW-SB
QMark SED Stainless Steel Fan-Forced Wall Heater 3410 BTU 120 Volt 1000 Watts SED1012C
King PX ComfortCraft Designer Pick-A-Watt Wall Heater 5120 BTU 120V PX1215-WD-R
King PX ComfortCraft Designer Pick-A-Watt Wall Heater 5971 BTU 208V PX2017-WD-R
King PX ComfortCraft Designer Pick-A-Watt Wall Heater 5971 BTU 240V PX2417-WD-R
King WHFC Ceiling Heater 120V 1000-500W Bright White - WHFC1210-BW
King WHFC Ceiling Heater 120V 1500-750W Bright White - WHFC1215-BW
King WHFC Ceiling Heater 240/208V 1000-500W/750-375W Bright White - WHFC2410-BW
King WHFC Ceiling Heater 240/208V 1500-750W/1125-562W Bright White - WHFC2415-BW
QMark LFK Commercial Fan-Forced Wall Heater 5118-6824 BTU 1.5/2 kW 208/240V 1 Phase LFK204F
QMark LFK Commercial Fan-Forced Wall Heater 5118-13649 BTU 1.5-4.0 kW 208/240V 1 Phase LFK404F
QMark LFK Commercial Fan-Forced Wall Heater 5118 BTU 1.5 kW 120V 1 Phase LFK151F
QMark LFK Commercial Fan-Forced Wall Heater 6142-16378 BTU 1.8-4.8 kW 208/240V 1 Phase LFK484F
King KTW Heater with Hi-Low Switch and Recessed Grill 120V 1500W - KTW1215-HLS-RG-SB
King KTW Heater with Hi-Low Switch and Recessed Grill 240-208V 1500/1125 Satin Black - KTW2415-HLS-RG-SB
King KTW Heater with Hi-Low Switch and Recessed Grill 120V 1500W Bright White - KTW1215-HLS-RG-BW
QMark CWH Commercial Fan-Forced Wall Heater 5118 BTU 1.5 kW 120V 1 Phase CWH3150F
King KTW Heater with Hi-Low Switch and Recessed Grill 240/208V 1500/1125 Bright White - KTW2415-HLS-RG-BW
King WSC Wall Heater with Single Pole Stat and Grill 120V 1500-750W Satin Black - WSC1215-T-SB
King PX ECO2S Designer Electronic Wall Heater 5120 BTU 120V PX1215-ECO-WD-R
King PX ECO2S Designer Electronic Wall Heater 5971 BTU 208V PX2017-ECO-WD-R
King PX ECO2S Designer Electronic Wall Heater 5971 BTU 240V PX2417-ECO-WD-R
QMark CWH Commercial Fan-Forced Wall Heater 5118-13649 BTU 1.5-4.0 kW 208/240V 1 Phase CWH3404F
QMark CWH Commercial Fan-Forced Wall Heater 5118-13649 BTU 1.5-4.0 kW 240/277V 1 Phase CWH3407F
QMark CWH Commercial Fan-Forced Wall Heater 6824-13649 BTU 2.0/4.0 kW 208V 1 Phase CWH3408F
QMark SSHO Commercial SmartSeries High-Output Wall Heater 13650 BTU 1.8/4.0 kW 277V SSHO4007
How Do I Choose the Right Wall Mount Heater Size for My Space?
Calculating proper heater capacity starts with understanding your space's heat loss factors and desired temperature rise. A standard formula multiplies your room's cubic footage by the required BTU factor (typically 3-5 BTUs per cubic foot for moderate climates, 5-7 for colder regions). A 2,000 square foot warehouse with 20-foot ceilings needs approximately 120,000-200,000 BTUs of heating capacity, which you might achieve with multiple wall-mounted units strategically placed for optimal heat distribution. Consider factors like insulation quality, door traffic frequency, and ceiling height when sizing your system. Industrial spaces with poor insulation or frequent loading dock activity require 20-30% additional capacity to maintain consistent temperatures during peak operation hours.
What Installation Requirements Should I Plan For?
Wall mount electric heaters demand proper electrical infrastructure and strategic placement for safe, efficient operation. Most commercial units require dedicated 208/240V or 480V circuits with appropriate amperage based on heater wattage, typically installed by licensed electricians to meet local code requirements. Mounting height recommendations vary by model but generally range from 2-3 feet for optimal heat distribution and safety clearance from combustible materials. Units should maintain minimum clearances of 3 feet from ceilings and 6 inches from walls, with consideration for airflow patterns that avoid heating obstructions or creating uncomfortable hot spots near workstations. Planning for disconnect switches and thermostatic controls during initial installation saves significant retrofit costs later.
How Can Wall Mount Heaters Reduce My Operating Costs?
Modern wall mount electric heaters deliver zone heating capabilities that dramatically cut energy waste compared to central heating systems. By warming only occupied areas during specific shifts, facilities often reduce heating costs by 30-50% while maintaining comfortable working temperatures where employees actually need them. Units featuring built-in thermostats and programmable controls prevent energy waste during off-hours, while adjustable louvers direct heat precisely where needed rather than warming empty ceiling space. Electric heaters also eliminate combustion-related maintenance costs, ventilation requirements, and fuel storage concerns associated with gas alternatives. The absence of moving parts in many infrared and ceramic models means fewer breakdowns and lower long-term maintenance expenses compared to forced-air systems.
Why Shop at Industrial Fans Direct for Wall Mount Electric Heaters?
Industrial Fans Direct brings over 20 years of experience matching heating solutions to specific industrial challenges, backed by relationships with leading manufacturers that translate into competitive pricing and reliable availability. Our technical team provides detailed heat load calculations and placement recommendations, helping you avoid costly sizing mistakes that plague many installations. With our Low Price Guarantee, you receive both value pricing and knowledgeable support from specialists focused on finding the right solution. Most orders ship free within 24-48 hours from strategically located warehouses, minimizing downtime for critical heating needs.

















































